130B2861 Ahf db 034 380 60 20 a
The VLT Advanced Harmonic Filter AHF 005 / AHF 010 model with order code 130B2861 is offered in the Filters and Power Quality › VLT Advanced Harmonic Filter AHF 005 / AHF 010 group. A cost-effective total solution merging VLT drives with AHF filter technology. It cuts harmonic current distortion to 5% (AHF 005) or 10% (AHF 010) THiD at full load, with efficiency above 0.98 up to 250 kW.
Technical data and ordering information for this Inverter Store catalogue item are given below.
Series Information
General characteristics of the VLT Advanced Harmonic Filter AHF 005 / AHF 010 platform:
- Series Power Range: Efficiency above 0.98 for systems up to 250 kW
- Series Voltage Range: 380-415 VAC (50 Hz); 440-480 VAC (60 Hz); 500-525 VAC (50 Hz); 690 VAC (50 Hz)
- Enclosure Options: IP20 standard, with IP21 / NEMA 1 upgrade available
- Ambient 5-40 C without derating
- Harmonic current distortion reduced to 5% THiD (AHF 005) or 10% THiD (AHF 010) at full load
- Overload capability 160% for 60 seconds
Technical Summary
| Order Code | 130B2861 |
|---|---|
| Product Series | VLT Advanced Harmonic Filter AHF 005 / AHF 010 |
| Brand | Danfoss |
| Category | Filters and Power Quality › VLT Advanced Harmonic Filter AHF 005 / AHF 010 |
Main Strengths
- AHF 010 matches 12-pulse rectifier levels
- Passive operation with efficiency greater than 0.98 up to 250 kW
- Compact design gives a smaller footprint and higher harmonic reduction than traditional filters
- No startup adjustments and no routine maintenance required
- A single filter can protect multiple drives
The full model code determines the final configuration of the unit.
Application Examples
It is suitable for the following applications:
- Systems needing IEEE 519 compliance
- Systems up to 250 kW
- Harmonic mitigation for VLT AC drive installations
- Retrofit of existing drive installations
Write to Us
For price, delivery time and technical questions, write to info@inverterstore.ru.